feat: add Modbus drivers for Jig, TPU, and RPU
This commit is contained in:
@@ -0,0 +1,40 @@
|
|||||||
|
import time
|
||||||
|
from dataclasses import dataclass
|
||||||
|
|
||||||
|
from drivers.modbus_device import ModbusDevice, ModbusDeviceError
|
||||||
|
|
||||||
|
|
||||||
|
@dataclass
|
||||||
|
class Position:
|
||||||
|
x: int
|
||||||
|
y: int
|
||||||
|
z: int
|
||||||
|
|
||||||
|
def __str__(self):
|
||||||
|
return f"(x={self.x}, y={self.y}, z={self.z})mm"
|
||||||
|
|
||||||
|
|
||||||
|
class JigMovementError(ModbusDeviceError):
|
||||||
|
pass
|
||||||
|
|
||||||
|
|
||||||
|
class Jig(ModbusDevice):
|
||||||
|
def __init__(self, port, registers, slave_id=0x10):
|
||||||
|
super().__init__(port, "Jig", registers, slave_id=slave_id)
|
||||||
|
|
||||||
|
def move_to_position(self, position, wait_time=5):
|
||||||
|
try:
|
||||||
|
self.write_holding_register(self._addr("X POSITION"), position.x)
|
||||||
|
self.write_holding_register(self._addr("Y POSITION"), position.y)
|
||||||
|
self.write_holding_register(self._addr("Z POSITION"), position.z)
|
||||||
|
self.write_coil(self._addr("MOVE TO POSITION"), True, verify=False)
|
||||||
|
if wait_time > 0:
|
||||||
|
time.sleep(wait_time)
|
||||||
|
except ModbusDeviceError as exc:
|
||||||
|
raise JigMovementError(f"failed to move to {position}") from exc
|
||||||
|
|
||||||
|
def get_current_position(self):
|
||||||
|
x = self.read_holding_register(self._addr("X POSITION"))
|
||||||
|
y = self.read_holding_register(self._addr("Y POSITION"))
|
||||||
|
z = self.read_holding_register(self._addr("Z POSITION"))
|
||||||
|
return Position(x, y, z)
|
||||||
@@ -0,0 +1,186 @@
|
|||||||
|
import struct
|
||||||
|
import time
|
||||||
|
|
||||||
|
from pymodbus.client import ModbusSerialClient
|
||||||
|
from pymodbus.exceptions import ModbusException
|
||||||
|
|
||||||
|
|
||||||
|
class ModbusDeviceError(Exception):
|
||||||
|
pass
|
||||||
|
|
||||||
|
|
||||||
|
class ModbusConnectionError(ModbusDeviceError):
|
||||||
|
pass
|
||||||
|
|
||||||
|
|
||||||
|
class ModbusReadError(ModbusDeviceError):
|
||||||
|
pass
|
||||||
|
|
||||||
|
|
||||||
|
class ModbusWriteError(ModbusDeviceError):
|
||||||
|
pass
|
||||||
|
|
||||||
|
|
||||||
|
class ModbusDevice:
|
||||||
|
FLOAT_VERIFY_TOLERANCE = 0.01
|
||||||
|
|
||||||
|
def __init__(self, port, device_name, registers=None, slave_id=0x10, baudrate=9600, timeout=3,
|
||||||
|
retries=3, retry_delay_s=0.2):
|
||||||
|
self.port = port
|
||||||
|
self.device_name = device_name
|
||||||
|
self.registers = registers or {}
|
||||||
|
self.slave_id = slave_id
|
||||||
|
self.retries = retries
|
||||||
|
self.retry_delay_s = retry_delay_s
|
||||||
|
try:
|
||||||
|
self.client = ModbusSerialClient(port=port, baudrate=baudrate, parity="N", stopbits=1, bytesize=8, timeout=timeout)
|
||||||
|
if not self.client.connect():
|
||||||
|
raise ModbusConnectionError(f"failed to connect to {device_name} on {port}")
|
||||||
|
except ModbusException as exc:
|
||||||
|
raise ModbusConnectionError(f"error connecting to {device_name} on {port}") from exc
|
||||||
|
|
||||||
|
def _addr(self, label):
|
||||||
|
try:
|
||||||
|
return self.registers[label].address
|
||||||
|
except KeyError:
|
||||||
|
raise ModbusDeviceError(f"unknown register label for {self.device_name}: {label}")
|
||||||
|
|
||||||
|
def _retry(self, action):
|
||||||
|
last_exc = None
|
||||||
|
for attempt in range(self.retries):
|
||||||
|
try:
|
||||||
|
return action()
|
||||||
|
except (ModbusDeviceError, ModbusException) as exc:
|
||||||
|
last_exc = exc
|
||||||
|
if attempt < self.retries - 1:
|
||||||
|
time.sleep(self.retry_delay_s)
|
||||||
|
raise last_exc
|
||||||
|
|
||||||
|
# ---- raw reads (retried on failure) ----
|
||||||
|
|
||||||
|
def read_coil(self, address):
|
||||||
|
def _do():
|
||||||
|
res = self.client.read_coils(address, count=1, device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusReadError(f"{self.device_name}: failed to read coil {address}")
|
||||||
|
return res.bits[0]
|
||||||
|
return self._retry(_do)
|
||||||
|
|
||||||
|
def read_holding_register(self, address):
|
||||||
|
def _do():
|
||||||
|
res = self.client.read_holding_registers(address, count=1, device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusReadError(f"{self.device_name}: failed to read holding {address}")
|
||||||
|
return res.registers[0]
|
||||||
|
return self._retry(_do)
|
||||||
|
|
||||||
|
def read_holding_register_float(self, address):
|
||||||
|
def _do():
|
||||||
|
res = self.client.read_holding_registers(address, count=2, device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusReadError(f"{self.device_name}: failed to read holding float {address}")
|
||||||
|
return struct.unpack(">f", struct.pack(">HH", res.registers[0], res.registers[1]))[0]
|
||||||
|
return self._retry(_do)
|
||||||
|
|
||||||
|
def read_input_register(self, address):
|
||||||
|
def _do():
|
||||||
|
res = self.client.read_input_registers(address, count=1, device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusReadError(f"{self.device_name}: failed to read input {address}")
|
||||||
|
return res.registers[0]
|
||||||
|
return self._retry(_do)
|
||||||
|
|
||||||
|
def read_signed_input_register(self, address):
|
||||||
|
val = self.read_input_register(address)
|
||||||
|
return val - 65536 if val > 32767 else val
|
||||||
|
|
||||||
|
def read_input_register_float(self, address):
|
||||||
|
def _do():
|
||||||
|
res = self.client.read_input_registers(address, count=2, device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusReadError(f"{self.device_name}: failed to read input float {address}")
|
||||||
|
return struct.unpack(">f", struct.pack(">HH", res.registers[0], res.registers[1]))[0]
|
||||||
|
return self._retry(_do)
|
||||||
|
|
||||||
|
# ---- writes, verified by reading the value back (whole write+verify retried on mismatch) ----
|
||||||
|
|
||||||
|
def write_coil(self, address, value, verify=True):
|
||||||
|
value = bool(value)
|
||||||
|
|
||||||
|
def _do():
|
||||||
|
res = self.client.write_coil(address, value, device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusWriteError(f"{self.device_name}: failed to write coil {address}")
|
||||||
|
if verify and self.read_coil(address) != value:
|
||||||
|
raise ModbusWriteError(f"{self.device_name}: write coil {address}={value} not verified")
|
||||||
|
self._retry(_do)
|
||||||
|
|
||||||
|
def write_holding_register(self, address, value):
|
||||||
|
value = int(value) & 0xFFFF # two's-complement wrap so negative (signed) values fit the uint16 wire format
|
||||||
|
|
||||||
|
def _do():
|
||||||
|
res = self.client.write_register(address, value, device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusWriteError(f"{self.device_name}: failed to write holding {address}")
|
||||||
|
if self.read_holding_register(address) != value:
|
||||||
|
raise ModbusWriteError(f"{self.device_name}: write holding {address}={value} not verified")
|
||||||
|
self._retry(_do)
|
||||||
|
|
||||||
|
def read_signed_holding_register(self, address):
|
||||||
|
val = self.read_holding_register(address)
|
||||||
|
return val - 65536 if val > 32767 else val
|
||||||
|
|
||||||
|
def write_holding_register_float(self, address, value):
|
||||||
|
def _do():
|
||||||
|
reg1, reg2 = struct.unpack(">HH", struct.pack(">f", value))
|
||||||
|
res = self.client.write_registers(address, [reg1, reg2], device_id=self.slave_id)
|
||||||
|
if res.isError():
|
||||||
|
raise ModbusWriteError(f"{self.device_name}: failed to write holding float {address}")
|
||||||
|
readback = self.read_holding_register_float(address)
|
||||||
|
if abs(readback - value) > self.FLOAT_VERIFY_TOLERANCE:
|
||||||
|
raise ModbusWriteError(
|
||||||
|
f"{self.device_name}: write holding float {address}={value} not verified (read back {readback})"
|
||||||
|
)
|
||||||
|
self._retry(_do)
|
||||||
|
|
||||||
|
# ---- generic label-based access (covers every register in self.registers) ----
|
||||||
|
|
||||||
|
def _register(self, label):
|
||||||
|
try:
|
||||||
|
return self.registers[label]
|
||||||
|
except KeyError:
|
||||||
|
raise ModbusDeviceError(f"unknown register label for {self.device_name}: {label}")
|
||||||
|
|
||||||
|
def read(self, label):
|
||||||
|
reg = self._register(label)
|
||||||
|
if reg.object_type == "coil":
|
||||||
|
return self.read_coil(reg.address)
|
||||||
|
if reg.object_type == "input":
|
||||||
|
if reg.data_type == "float":
|
||||||
|
return self.read_input_register_float(reg.address)
|
||||||
|
if reg.data_type == "int":
|
||||||
|
return self.read_signed_input_register(reg.address)
|
||||||
|
return self.read_input_register(reg.address)
|
||||||
|
if reg.object_type == "holding":
|
||||||
|
if reg.data_type == "float":
|
||||||
|
return self.read_holding_register_float(reg.address)
|
||||||
|
if reg.data_type == "int":
|
||||||
|
return self.read_signed_holding_register(reg.address)
|
||||||
|
return self.read_holding_register(reg.address)
|
||||||
|
raise ModbusDeviceError(f"{self.device_name}: unsupported object_type {reg.object_type!r} for {label!r}")
|
||||||
|
|
||||||
|
def write(self, label, value):
|
||||||
|
reg = self._register(label)
|
||||||
|
if reg.object_type == "coil":
|
||||||
|
self.write_coil(reg.address, value)
|
||||||
|
return
|
||||||
|
if reg.object_type == "holding":
|
||||||
|
if reg.data_type == "float":
|
||||||
|
self.write_holding_register_float(reg.address, value)
|
||||||
|
else:
|
||||||
|
self.write_holding_register(reg.address, value)
|
||||||
|
return
|
||||||
|
raise ModbusDeviceError(f"{self.device_name}: cannot write to object_type {reg.object_type!r} for {label!r}")
|
||||||
|
|
||||||
|
def close(self):
|
||||||
|
self.client.close()
|
||||||
@@ -0,0 +1,43 @@
|
|||||||
|
import time
|
||||||
|
|
||||||
|
from common.config_loader import load_garuda_registers
|
||||||
|
from drivers.modbus_device import ModbusDevice
|
||||||
|
|
||||||
|
DEFAULT_DATASETS = ["Sec_normal", "sec_flash"]
|
||||||
|
|
||||||
|
|
||||||
|
class Rpu(ModbusDevice):
|
||||||
|
"""Covers every register in Sec_normal + sec_flash by label via read()/write()
|
||||||
|
(inherited from ModbusDevice). Extra datasets can be added per-test via
|
||||||
|
extra_datasets. Only registers that need real logic beyond a 1:1 read/write
|
||||||
|
get a dedicated method below.
|
||||||
|
"""
|
||||||
|
|
||||||
|
Q128_DIVISOR = 128.0
|
||||||
|
REWRITE_PASSWORD_LO = 0xFEED
|
||||||
|
REWRITE_PASSWORD_HI = 0xCEE5
|
||||||
|
REWRITE_WAIT_S = 5
|
||||||
|
|
||||||
|
def __init__(self, port, extra_datasets=None, slave_id=0x10):
|
||||||
|
registers = load_garuda_registers(DEFAULT_DATASETS + list(extra_datasets or []))
|
||||||
|
super().__init__(port, "RPU", registers, slave_id=slave_id)
|
||||||
|
|
||||||
|
def set_charging(self, enable):
|
||||||
|
self.write_coil(self._addr("Enable_charger"), enable)
|
||||||
|
|
||||||
|
def set_runtime_voltage(self, volts):
|
||||||
|
self.write_holding_register(self._addr("Runtime_voltage_setting_Q128"), round(volts * self.Q128_DIVISOR))
|
||||||
|
|
||||||
|
def set_runtime_current(self, amps):
|
||||||
|
self.write_holding_register(self._addr("Runtime_current_setting_Q128"), round(amps * self.Q128_DIVISOR))
|
||||||
|
|
||||||
|
def read_error_code(self):
|
||||||
|
return (self.read("Error_code_hi") << 16) | self.read("Error_code_lo")
|
||||||
|
|
||||||
|
def read_shadow_error_code(self):
|
||||||
|
return (self.read("Shadow_error_code_hi") << 16) | self.read("Shadow_error_code_lo")
|
||||||
|
|
||||||
|
def rewrite_config(self):
|
||||||
|
self.write_holding_register(self._addr("PASSWORD_LO"), self.REWRITE_PASSWORD_LO)
|
||||||
|
self.write_holding_register(self._addr("PASSWORD_HI"), self.REWRITE_PASSWORD_HI)
|
||||||
|
time.sleep(self.REWRITE_WAIT_S)
|
||||||
@@ -0,0 +1,44 @@
|
|||||||
|
import time
|
||||||
|
|
||||||
|
from common.config_loader import load_fenghuang_registers
|
||||||
|
from drivers.modbus_device import ModbusDevice, ModbusDeviceError
|
||||||
|
|
||||||
|
DEFAULT_DATASETS = ["Pri_normal", "Debug", "event_log"]
|
||||||
|
|
||||||
|
# TPU_STATE values that allow modbus_to_config()/write_all_flash() to run
|
||||||
|
# (fenghuang-dsp/app/app_modbus/app_modbus.c update_modbus_input()).
|
||||||
|
# TPU_RUN_INV (charging) is NOT in this set - config writes are silently
|
||||||
|
# ignored while charging is active.
|
||||||
|
CONFIG_WRITABLE_STATES = {2, 10, 15, 16, 238} # READY, INITIALIZATION, DEBUG_CONFIG, TEST_MODE, ERROR
|
||||||
|
|
||||||
|
|
||||||
|
class Tpu(ModbusDevice):
|
||||||
|
"""Covers every register in Pri_normal + Debug + event_log by label via
|
||||||
|
read()/write() (inherited from ModbusDevice). More datasets can be added
|
||||||
|
per-test via extra_datasets. Only registers that need real logic beyond a
|
||||||
|
1:1 read/write get a dedicated method below.
|
||||||
|
"""
|
||||||
|
|
||||||
|
REWRITE_WAIT_S = 5
|
||||||
|
|
||||||
|
def __init__(self, port, extra_datasets=None, slave_id=0x10):
|
||||||
|
registers = load_fenghuang_registers(DEFAULT_DATASETS + list(extra_datasets or []))
|
||||||
|
super().__init__(port, "TPU", registers, slave_id=slave_id)
|
||||||
|
|
||||||
|
def wait_until_config_writable(self, timeout_s=10, poll_interval_s=0.5):
|
||||||
|
deadline = time.time() + timeout_s
|
||||||
|
while time.time() < deadline:
|
||||||
|
if self.read("Main_state") in CONFIG_WRITABLE_STATES:
|
||||||
|
return
|
||||||
|
time.sleep(poll_interval_s)
|
||||||
|
raise ModbusDeviceError(f"TPU did not reach a config-writable state within {timeout_s}s")
|
||||||
|
|
||||||
|
def read_error_code(self):
|
||||||
|
return (self.read("Error_code_HI") << 16) | self.read("Error_code_LO")
|
||||||
|
|
||||||
|
def read_shadow_error_code(self):
|
||||||
|
return (self.read("Shadow_Error_code_HI") << 16) | self.read("Shadow_Error_code_LO")
|
||||||
|
|
||||||
|
def rewrite_config(self):
|
||||||
|
self.write_coil(self._addr("rewrite_cfg_flash"), True, verify=False)
|
||||||
|
time.sleep(self.REWRITE_WAIT_S)
|
||||||
Reference in New Issue