Files
phoenix-regression-test/drivers/rpu.py
T

64 lines
2.5 KiB
Python

import time
from common.config_loader import load_garuda_registers
from drivers.modbus_device import ModbusDevice, ModbusDeviceError
DEFAULT_DATASETS = ["Sec_normal", "sec_flash", "event_log"]
# SEC_STATE values that allow modbus_to_config()/write_all_flash() to run
# (garuda-dsp/app/app_modbus/app_modbus.c update_modbus_input()).
# SEC_RUN (charging) is NOT in this set - config writes are silently ignored
# while charging is active.
CONFIG_WRITABLE_STATES = {1, 9, 238, 240, 241} # READY, PRE_READY, ERROR, DEBUG_READY, DEBUG_FREQ_CAL
class Rpu(ModbusDevice):
"""Covers every register in Sec_normal + sec_flash by label via read()/write()
(inherited from ModbusDevice). Extra datasets can be added per-test via
extra_datasets. Only registers that need real logic beyond a 1:1 read/write
get a dedicated method below.
"""
Q128_DIVISOR = 128.0
REWRITE_PASSWORD_LO = 0xFEED
REWRITE_PASSWORD_HI = 0xCEE5
REWRITE_WAIT_S = 5
def __init__(self, port, extra_datasets=None, slave_id=0x10):
registers = load_garuda_registers(DEFAULT_DATASETS + list(extra_datasets or []))
super().__init__(port, "RPU", registers, slave_id=slave_id)
def set_charging(self, enable):
self.write_coil(self._addr("Enable_charger"), enable)
def read_q128(self, label):
return self.read(label) / self.Q128_DIVISOR
def write_q128(self, label, value):
self.write(label, round(value * self.Q128_DIVISOR))
def set_runtime_voltage(self, volts):
self.write_q128("Runtime_voltage_setting_Q128", volts)
def set_runtime_current(self, amps):
self.write_q128("Runtime_current_setting_Q128", amps)
def read_error_code(self):
return (self.read("Error_code_hi") << 16) | self.read("Error_code_lo")
def read_shadow_error_code(self):
return (self.read("Shadow_error_code_hi") << 16) | self.read("Shadow_error_code_lo")
def wait_until_config_writable(self, timeout_s=10, poll_interval_s=0.5):
deadline = time.time() + timeout_s
while time.time() < deadline:
if self.read("Main_state") in CONFIG_WRITABLE_STATES:
return
time.sleep(poll_interval_s)
raise ModbusDeviceError(f"RPU did not reach a config-writable state within {timeout_s}s")
def rewrite_config(self):
self.write_holding_register(self._addr("PASSWORD_LO"), self.REWRITE_PASSWORD_LO)
self.write_holding_register(self._addr("PASSWORD_HI"), self.REWRITE_PASSWORD_HI)
time.sleep(self.REWRITE_WAIT_S)